Power Sequencer with overvoltage protection and mains filter, 16 A, 6 x IEC C13, Jack socket for I/O-Switch, GUDE 8112-2
Increased operational reliability due to sequential switching of 6 consumers
3The Expert Power Sequencer 8112 Series enables automatic switching of up to 6 electrical devices. The series consists of four variants, each with 6 load outputs on the front:
8112-1: 6x IEC C13
8112-2: 6x IEC C13 with overvoltage protection and mains filter
8112-3: 6x safety sockets type F (CEE 7/3)
8112-4: 6x safety sockets type F (CEE 7/3) with overvoltage protection and mains filter
The consumers connected to the output connectors can be switched on sequentially and switched off in reverse order by an automatic switching routine. The switching sequence is triggered by operating the slide switch on the front of the 19-inch device. The power ports are switched one after the other with a delay of 3 seconds each. This switching time interval can be individually configured for each outlet.
The integrated overvoltage protection type 3 of the Expert Power Sequencer 8112-2 and 8112-4 effectively prevents defects of the PDU and the connected loads. In addition, the mains filter in both power distribution units ensures that interference noises from loudspeakers or audio amplifiers are avoided.
- Sequential switching by simply pressing a button
- Individual configuration of the switching interval
- Avoid critical inrush currents
- Effectively reduce electricity costs
- More safety due to Surge Protection Device (type 3)
- Minimize noise interference through built-in mains filter (8112-2 und 8112-4)
- Switch up to 6 loads (IEC C13 or Schuko type F)
Applications
• Increasing operational reliability by avoiding excessive inrush currents, e.g. in amplifiers, media technology installations and LED walls
• Saving electricity costs by switching off devices with high standby consumption such as receivers, servers, external hard drives, displays and audio amplifiers
• Ensuring that critical devices, such as an audio amplifier, are switched on last and switched off first. The typical and unpleasant popping noises, which can also damage loudspeakers and amplifiers, are a thing of the past.
• The jack connector allows the connection of an external push button and enables the control outside of a 19 inch cabinet
Locations
• AV environments with audio components such as in conference rooms, theater halls, auditoriums and small meeting rooms
• Installations for display and LED walls
• IT facilities such as in network and server cabinets (19 inch)
• AV installations in the smart home sector with amplifiers, loudspeakers and beamers
Features
- 6 power ports switchable in a controlled switching sequence by keystroke on the device or by external push-button
- Sequential switching of connected loads with a delay of 3s between adjacent outputs
- Delay intervals between the switching processes can be set individually
- Inrush current peaks during simultaneous switching operations and tripping of upstream fuses are prevented
- Integrated overvoltage protection type 3 (SPD according to EN61643-1) prevents damage to the device and connected loads
- Jack socket allows connection of external switches or I/O contacts and enables remote control of the switching routine
- Integrated mains filter (8112-2 und 8112-4) prevents interference currents and thus eliminates loss of signal quality for connected devices such as loudspeakers, amplifiers and beamers
- Low internal power consumption
- Developed and manufactured in Germany
Electrical Connections |
1 Power supply safety socket type E/F (CEE 7/7, max. 16 A, 230 V) |
6 Power Ports IEC C13 (max. 10 A) for 8112-1/8112-2 |
6 Power Ports safety sockets type F, CEE 7/3 (max. 16 A) for 8112-3/8112-4 |
1 Jack connector for external push-button and I/O contacts |
Technical Details |
19 inch, 1 height unit |
8112-1/8112-3: LxHxD 43.9 x 4.4 x 6.2 cm (without mounting brackets) |
8112-1/8112-3: Weight approx. 1.6 kg |
8112-2/8112-4: LxHxD 43.9 x 4.4 x 11.2 cm (without mounting brackets) |
8112-2/8112-4: Weight approx. 2.1 kg |
Cable length: 2 m |
Operating temperature: 0-50 °C |
Storage temperature: -20 - 70 °C |
Relative humidity: 0 - 95 % (non-condensing environment) |
Order code |
8112-1 (IEC C13 connectors) |
8112-2 (IEC C13 connectors, SPD, mains filter) |
8112-3 (Safety sockets) |
8112-4 (Safety sockets, SPD, mains filter) |
Scope of delivery |
Expert Power Sequencer 8112-1 / 8112-2 / 8112-3 / 8112-4 |
Quick start guide |